Flanges› Dimensions› AWWA› AWWA C207 Class B› Class B Blind Flange

AWWA C207 Class B
Blind Flange

AWWA C207-18 Class B Ring-Type Slip-On Flange Technical Drawing
DIMENSIONAL DATA
NPS OD of a Flange
(A)
ID of a
Flange (B)
Number of
Bolts
Diameter of
Bolt Circle (C)
Diameter of
Bolts
Thickness of Flange
Class B (T)
4 9.00 4.57 8 7.50 0.625 0.625
5 10.00 5.66 8 8.50 0.750 0.625
6 11.00 6.72 8 9.50 0.750 0.688
8 13.50 8.72 8 11.75 0.750 0.688
10 16.00 10.88 12 14.25 0.875 0.688
12 19.00 12.88 12 17.00 0.875 0.719
14 21.00 14.19 12 18.75 1.000 0.791
16 23.50 16.19 16 21.25 1.000 0.892
18 25.00 18.19 16 22.75 1.125 0.950
20 27.50 20.19 20 25.00 1.125 1.040
22 29.50 22.19 20 27.25 1.250 1.132
24 32.00 24.19 20 29.50 1.250 1.216
26 34.25 24 31.75 1.250 1.307
28 36.50 28 34.00 1.250 1.398
30 38.75 28 36.00 1.250 1.477
32 41.75 28 38.50 1.500 1.581
34 43.75 32 40.50 1.500 1.661
36 46.00 32 42.75 1.500 1.751
38 48.75 32 45.25 1.500 1.853
40 50.75 36 47.25 1.500 1.933
42 53.00 36 49.50 1.500 2.023
44 55.25 40 51.75 1.500 2.114
46 57.25 40 53.75 1.500 2.194
48 59.50 44 56.00 1.500 2.285
50 61.75 44 58.25 1.750 2.377
52 64.00 44 60.50 1.750 2.468
54 66.25 44 62.75 1.750 2.559
60 73.00 52 69.25 1.750 2.820
66 80.00 52 76.00 1.750 3.092
72 86.50 60 82.50 1.750 3.353
TABLE NOTE

1. Ring flanges may be overbored or counterbored to accommodate larger outside-diameter (OD) pipe than shown as nominal. This is done to allow a clear inside diameter (ID) after cement-mortar lining. Wrench clearance between the pipe OD and bolt circle, as well as sufficient gasket seating area, must be maintained.

2. Metric conversion—nominal pipe size: in. × 25 = mm; dimensions: in. × 25.4 = mm; psi × 6.895 = kPa.

Need AWWA C207 Class B Blind Flanges for Your Project?

Precision Engineering. Technical Expertise. Global Supply.